- E-Factor - Essential for general understanding, graphically plotting relations between two devices relative to each other simultaneously with respect to the colorimetric target
- Primaries
- Overprints
- Greys
- Tints divided into highlights, mid-tones, and shadows
It is very effective way to demonstrate how 2 output devices are close one to another.
Setting comparison parameters is very important, we can choose to compare the last measurement only, the more recent measurement group or the last 5 measurements. This is important because it allows us to examine not only deviations but also variances of printing.

- Aimpoint mismatch — two compared devices have different goals — comparing apples and oranges
If one track is set to Gracol, another to uncoated paper (two different ICC profiles) or SCCA caused strong intervention into colorimetric aims comparison may bring an unreal picture.

- Questionable results! If Deviation or variation is above 10 there is a very limited sense to make any comparison. The device is in very bad condition or just measurement fails for any reason. Examine track.

- Measurement condition mismatch — don't mix Mo. M1, M2, and M3 data.